Mediana A15 HeartOn AED

£895.00 + VAT

Mediana A15 HeartOn AED

Four times as many women die as a result of a heart attack than they do from breast cancer.

• In the UK, twelve people under the age of 35 die every week due to sudden cardiac arrest.
• For every minutes delay, a victim's chance of surviving a sudden cardiac arrest drops by 7-10%.
• 70% of cardiac arrests occur outside of a hospital environment.
• Almost 95% of sudden cardiac arrest victims die before reaching hospital.
• CPR effectively administered immediately after sudden cardiac arrest, can double a victim's chance of survival.
• Seven out of ten cardiac arrests occur outside of hospital. Currently in the UK, only 2-3% of these people survive.
• Around 270,000 people suffer a heart attack in the UK each year. Of these, up to a third will die before reaching hospital.
• The Department of Health has a target of placing 3,000 new defibrillators in public places in England.
• Explorer, Sir Ranulph Fiennes, is alive today largely thanks to a defibrillator located at Bristol airport.
• Passive smoking increases the risk of developing coronary heart disease by up to 30%.
• Early defibrillation can triple a victims chance of survival.

SPECIFICATIONS

Defibrillation electric shockWaveform: Biphasic Truncated Exponential (BTE)
waveform (Impedance compensation)
Energy: Adult: 185 to 200J (±5%)
Paediatric: 45 to 50J (±5%)
Operating Mode: Semi-Auto

ECG
Lead: II (RA, LL)
Patient Impedance: 25 to 175ohm
Detection V/F more than 200?V
V/T more than 160 per min
Indication

CONTROLSStandard: Open (power) switch, shock button,
Adult/Paediatric mode switch

INDICATORS
Visible: ICON Indicator, Status LCD (unit status,
battery status, temperature status),
LED (Adult/Paediatric mode switch LED)
Audible: Speaker (voice prompt), Beep (CPR indication)
Physica l
Dimensions: 294H x 240W x 95mmD
Weight: Approx. 2.65kg (including battery,
excluding pads)
Self Test
Cycle: Every 24 hours, 1 week, 1 month
Power on self test, battery insertion self test
Test Result: Status LCD displays ‘O’ / ‘X’
Data Bac kup and Communication
Standard SD card, IR communication port
Accessory Specifications

ADULT/PAEDIATRIC PADSStandby Life: 2 years from date of manufacture
Electrodes: Disposable pads
Placement: Adult: Anterior-lateral
Paediatric: Anterior-posterior
Minimum active gel area: 80cm2 +/-5%
Cable Length: Approx. 1.8m
Environmental Conditions
Temperature: Operation: 0 to 43°C (32 to 109.4°F)
Storage: 0 to 43°C (32 to 109.4°F)
Relative Humidity: 5 to 95% RH (non-condensing)

BATTERY
Type: LiMnO2, disposable, long-life primary cell
Voltage/Capacity: 15V, 4200 mAh
Shelf Life: 2 years from date of manufacture
(in the original packaging)
Standby Life: 5 years from date of manufacture
(inserted in the AED)
Discharge: A minimum of 200 shocks
(except the CPR period between the
defibrillation therapy) or 10 hours of
operating time at 20°C
Environmental Conditions
Temperature: Operation: 0 to 43°C (32 to 109.4°F)
Storage: 0 to 43°C (32 to 109.4°F)
Relative Humidity: 5 to 95% RH (non-condensing)