Zoll AED Pro

£2,295.00 + VAT

Zoll AED Pro

The most rugged, full-featured AED for professional rescuers designed with advanced capabilities, the ZOLL AED Pro® supports Basic Life Support as well as Advanced Life Support professionals. A high-resolution LCD display allows responders to visualise a patient's ECG while utilising a 3-lead monitoring cable.

Unique to ZOLL AEDs is a real-time feedback mechanism, known as Real CPR Help® which allows rescuers to see and hear how well they are performing the rate and depth of chest compressions during CPR.

Features & Benefits:

  • Rugged construction and exceptional durability support the needs of Basic Life Support providers
  • Manual override option satisfies Advanced Life Support professionals
  • Superior design and rubber over-molds, built to withstand harsh environments.
  • Exceptionally resistant to dust and water jets (IP55 Rating)
  • The only AED in the industry to withstand a 1.5-meter drop test
  • Available as semi-automatic with manual override or semi-automatic only.
  • Built-in 7-hour memory or USB memory technology allows virtually unlimited data storage capacity and maximum flexibility for data management and transfer
  • Electrodes and batteries compatible with ZOLL’s professional range of EMS and hospital defibrillators
  • ECG monitoring with 3-lead cable and high-quality display.
  • Real CPR Help with instant feedback on the rate and depth of chest compressions during CPR through ZOLL's unique one-piece CPR-D•padz
  • The AED Pro can defibrillate children up to eight years of age, using the pedi•padz II® electrodes. When the pedi•padz II are connected, the AED Pro recognises that a paediatric rescue is in progress.
  • Automatic self-testing assures constant state of readiness

Designed with advanced capabilities, the ZOLL AED ProTM supports Basic Life Support as well as Advanced Life Support professionals. A high-resolution LCD display allows responders to visualize a patient’s ECG while utilizing a 3-lead monitoring cable.

  • Instantaneous Feedback
    • AED Pro uses ECG Electrodes for monitor- ing and CPR-D•padz for monitoring and defibrillation.
    • AED Pro LCD provides complete information for all levels of rescuers.
    • The AED Pro* is the first defibrillator designed for professional responders with instantaneous feedback on CPR chest compressions. ZOLL’s unique real-time feedback mechanism, including an adaptive metronome and screen display, helps rescuers achieve optimum rate and depth compression levels through audible and visual prompts.
  • AED PRO Specifications
    • ECG Monitoring
    • Patient Connection: 3-lead ECG cable.
    • Input Selection: Fully defibrillator protected.
    • ECG Size: Automatic Control (AUD) gain. Heart Rate: 30-300 bpm ±5%.
  • Display
    • Screen Type: High-resolution LCD display.
    • Screen Size: 3.02 inches W x 2.27 inches H.
    • Sweep Speed: 25 mm/sec.
    • Viewing Time: 3 seconds.
    • Displayed Information:
      • Heart rate
      • ECG waveform
      • Text prompts
      • CPR bar graph
      • Battery gauge
      • Elapsed time
      • Number of shocks delivered
  • Event Documentation
    • Type: Internal non-volatile memory.
    • Memory Capacity:
      • With audio recording enabled, 20 minutes of ECG and operator and device actions
      • Without audio recording, 7 hours of ECG data or up to 4 patient records. Unlimited data storage with USB key.
    • Event Review & Reporting: RescueNetTM Code Review software version 3.30 or higher.
    • Communications: IrDA infrared wireless for communication with personal computer.
  • Defibrillator
    • Waveform: ZOLL Rectilinear BiphasicTM waveform.
    • Energy:
      • 50, 70, 85 (pediatric)
      • 120, 150, 200 joules (adult) preconfigured
      • Charge Time:
        • Less than 10 seconds with a new fully chargedbattery.
        • Depleted batteries will result in a longer defibrillator charge time.
    • Energy Display: Monitor display indicates selected energy in manual mode only.
    • AED Function: Auto analyze and charge x3 with programmable auto energy level selection, screen prompts, and voice prompts.
    • Electrodes:
      • CPR-D•padz, stat•padz IITM, and Pediatric pedi•padz IITM packaged in pairs.
      • CPR-D•padz one-piece electrode provides feedback on rate and depth of chest compressions.
    • Manual: Energy selection user configurable, 120, 150, 200 J adult and 50, 70, 85 J pediatric.
    • Semi-Automatic: Evaluates electrode connection and patient ECG to determine if defibrillation is required.
    • Shockable Rhythms: Ventricular fibrillation with amplitude >100 uV and wide complex ventricular tachycardia with rates greater than 150 bpm (adult) and greater than 200 bpm (pediatric).
    • Defibrillation Pads Impedance Measurement Range: 10-300 ohms.
    • Prompts: Audible voice prompts and text messages guide user through complete sequence of operation.
    • Controls: ON/OFF, Shock, Softkeys.
  • Battery Options
    • Type: Rechargeable, sealed lead acid.
    • Recharge Time: 4 hours or less with a ZOLL Power-Charger 4x4 or 1x1 Battery Charger.
    • Operating Time: For a new, fully charged battery pack at 20° C: 170 defibrillator discharges at maximum energy, or 6 hours continuous ECG monitoring.
    • Type: Sealed, disposable lithium manganese.
    • Operating Time: 300 defibrillator charges at maximum energy or 13 hours continuous ECG monitoring.
  • General
    • Size:3in(7.6cm)x9.2in(23.5cm)x 9.4in (23.9 cm) deep.
    • Weight: < 6.5 lbs with disposable battery and electrodes (2.9 kg).
    • Design Standards: Meets or exceeds AAMI DF-80, EN 60601-1, EN 60601-1-2.
    • Patient Safety: All patient connections are electrically isolated.
  • Environmental
    • Operating Temperature: 0° C to 50° C.
    • Storage and Shipping Temperature: -30° C to 70° C.
    • Humidity: 10% to 95% relative humidity, non-condensing.
    • Vibration: MIL Std. 810F, Minimum Helicopter Test.
    • Shock: IEC 68-2-27; 100G.
    • Material/Water Ingress: IEC 60529, IP55.
    • ElectromagneticCompatibility(EMC):CISPR; 11ClassB Rated and Conducted Emissions.
    • Electromagnetic Immunity: AAMI DF-80; IEC 60601.
    • Electrostatic Discharge: IEC 61000-4-2.
    • Conducted Susceptibility: IEC 61000-4-6.